Anker SOLIX E10 Battery Backup Kit (No Solar) | 7.68kW 120/240V | 18.43kWh Battery

Price range: $10,395.00 through $11,995.00

-

A battery backup kit built around the Anker SOLIX E10.

  • 7.68 kW continuous 120/240V split-phase output
  • Storage: 18.43 kWh (3 × 6.144 kWh Wall/Floor-Mount) Anker SOLIX B6000 6.144 kWh battery modules
  • Home connection: Power Dock or Smart Inlet Box
  • Grid-connected battery backup: charges from the grid now, add solar later

Solar panels not included.

SKU: WEB-PARENT-ANKER-SOLIX-E10-BATTERY-BACKUP-KIT-NO-SOLAR Categories: , , Brand:

Home Backup · Solar + Storage

Anker SOLIX E10 Battery Backup Kit (No Solar) | 7.68kW 120/240V | 18.43kWh Battery

This kit is built around the Anker SOLIX E10, delivering 7.68 kW of continuous 120/240V split-phase output and 18.43 kWh (3 × 6.144 kWh Wall/Floor-Mount) of storage.

At a Glance
  • 7.68 kW continuous AC output, 120/240V split-phase
  • Surge capacity up to 37.2 kW for motor starting
  • Battery options: 18.43 kWh (3 × 6.144 kWh Wall/Floor-Mount) (Anker SOLIX B6000 6.144 kWh battery modules)
  • Home connection: Power Dock or Smart Inlet Box
  • Grid-connected battery backup: charges from the grid now, add solar later

Choose Your Configuration

Battery Storage 18.43 kWh (3 × 6.144 kWh Wall/Floor-Mount)
Rack-Mount batteries install in a battery rack or cabinet; Wall/Floor-Mount batteries mount on a wall or stand on the floor.
Backup Interface Power Dock
Smart Inlet Box

Options are offered in specific combinations; available combinations are shown in the selector above.

System Overview

It connects to the grid for charging and backup but does not export power. This battery-only kit charges from the grid and backs up your home during outages; compatible solar can be added later.

Ideal Applications

  • Outage backup for the essentials plus kitchen circuits, microwave, fans and garage door
  • Extended-stay off-grid cabins

What’s Included

  • One Anker SOLIX E10
  • Anker SOLIX B6000 6.144 kWh battery modules (battery configurations), with mounting and battery cabling
  • Power Dock or Smart Inlet Box (per configuration)
Installation note: Site-specific wire and conduit, breakers, service and interconnection equipment, and permitting materials may be required. Utility and AHJ requirements vary; final design must follow manufacturer instructions and applicable code.
Weight N/A
Dimensions 72 × 48 × 54 in
Brand

Inverter Platform

Anker SOLIX E10

Inverter Quantity

Single

Continuous Output

7.68 kW

Inverter Size (KW)

5KW-10KW

Output (V)

120V/240V

Grid Connection

Grid-Connected Backup (No Export)

Generator Compatible

Yes

Inverter Type

All-in-one Inverter

Battery Capacity (KWH)

10KWH-20KWH

Battery Storage

18.43 kWh

Rapid Shutdown

None

Backup Interface

Power Dock, Smart Inlet Box

What Can It Power?

Built around the Anker SOLIX E10, a home backup system with expandable battery modules, this kit delivers 7.68 kW of continuous 120/240V split-phase output.

7.68 kW
Continuous output, 120/240V split-phase
37.2 kW
Surge for motor starting
18.43 kWh
Battery storage options
What you can run
Everyday essentials

0.5–1.5 kW

Refrigerator and freezer, LED lights, ceiling fans, phone and laptop charging, modem, router and TV. These small and cycling loads are the starting point for long outage coverage.

Kitchen, laundry & larger loads

1.5–5 kW each

Microwave, coffee maker, washer or dishwasher as needed. An electric water heater, dryer, oven or range can use a large share of the output, so stagger them instead of running them together.

Cooling, pumps & shop tools

Check starting current

A compatible mini-split, central HVAC, well pump or shop tool may run when its running demand and starting current fit within 7.68 kW continuous and 37.2 kW surge. Check the actual equipment; tonnage or horsepower alone doesn’t confirm it. A soft starter can help some compressors.

Illustrative operating mixes
Refrigerator/freezer, LED lights, internet, TV and fans0.5–1.5 kW
Essentials + microwave or coffee maker2–3.5 kW while it runs
Essentials + a smaller inverter mini-split1.5–3 kW
Essentials + a 4.5 kW electric water heater5–6 kW while heating
Plan around the limits
Add up the loads that run at the same time and allow for motor starts. For a 7.68 kW split-phase system, keep loads balanced across the two 120V legs: a heavily loaded leg can reach its limit before the total does. A larger battery adds runtime but doesn’t raise the inverter’s output. Examples are planning illustrations, not guaranteed appliance packages.

How Long Will It Run?

Battery size sets how much energy you have. These battery-only estimates use 80% of nominal storage delivered to loads (14.74 kWh from 18.43 kWh).

0.5 kW · Lean essentials / light overnight use
18.43 kWh

29.5 hrs

1 kW · Essentials with more appliance use
18.43 kWh

14.7 hrs

2 kW · Moderate household use
18.43 kWh

7.4 hrs

3.8 kW · Heavy sustained use
18.43 kWh

3.9 hrs

4 kW · Higher sustained use
18.43 kWh

3.7 hrs

7.68 kW · Full rated output
18.43 kWh

1.9 hrs

Runtime = usable battery energy ÷ average load, starting full, with no solar, grid or generator. Average load includes cycling: a 1 kW appliance running half the time averages about 0.5 kW. Actual results depend on settings, battery condition, temperature and system consumption.

At 12 kWh per day
1.2 days on 18.43 kWh
At 24 kWh per day
0.6 days on 18.43 kWh

Cooling, heating and electric water heating can change daily totals substantially.

Charging Without Included Solar

This kit doesn’t include solar panels. It charges from the grid or a generator, and compatible solar can be added later.

When Solar Isn’t Enough

Utility available
Your home runs on the grid as usual while solar and the grid keep the batteries charged. The system does not export to the utility.
Grid outage: solar + battery
The system supplies only the circuits connected to its backup output, from solar and stored energy. Plan for the 7.68 kW output limit, battery discharge limits and motor starts, and shed large loads to extend runtime. A properly configured compatible generator can carry extended low-sun periods (not included).

Why This System?

The Anker SOLIX E10 Battery Backup Kit (No Solar) is built around the Anker SOLIX E10, a home backup system with expandable battery modules. Match the configuration to your daily energy use, the loads that run together and your installation.

7.68 kW for a useful mix of loads

120/240V split-phase output runs common household circuits and compatible 240V equipment. Manage what runs together and check motor starts for HVAC, pumps or shop tools.

Smart Inlet Box or Power Dock

Choose how the system connects to your home’s circuits.

Expandable battery modules

Add B6000 modules for more runtime.

High surge capacity

Strong motor starting for pumps and HVAC within its rating.

Choose Your Size

No solar included · 14.74 kWh usable · Power Dock or Smart Inlet Box
18.43 kWh

Battery-only backup: charge from the grid now, add solar later.

Only the combinations shown in the product selector are offered. Every option uses the same Anker SOLIX E10 configuration.

Plan the system around your site
This platform doesn’t sell excess power back to the utility. Solar panels, site-specific electrical materials and installation are additional.

Other Sizes on This Platform

Dual Anker SOLIX E10 Home Backup Solar Kit | 15.36kW 120/240V | 14.4kW Solar | 36.86kWh Battery
Anker SOLIX E10 Home Backup Solar Kit | 7.68kW 120/240V | 6.4–8kW Solar | 12.29–30.72kWh Battery

Reference: Anker SOLIX E10 manufacturer information.

Frequently Asked Questions

Does this kit include batteries?
Yes: 18.43 kWh (3 × 6.144 kWh Wall/Floor-Mount) of Anker SOLIX B6000 6.144 kWh battery modules, per the option you choose.
Will it power my home during an outage?
Yes, for the circuits connected to its backup output (or the whole home with a whole-home interface).
What output does it provide?
7.68 kW continuous at 120/240V split-phase.
Can I sell excess solar to the utility?
No. This system does not export power to the grid.
Can I connect a generator?
Yes. Use an inverter-style generator (3–5% THD) with 2-wire auto-start for automatic control. Generator not included.
Are all breakers, wire and conduit included?
Not necessarily. Site-specific wire, conduit, breakers, service upgrades and interconnection hardware may be required.
How much does weather matter?
Solar production drops in cloudy or winter weather; plan on a generator or grid charging for long low-sun periods.
Do I need permits or utility approval?
Most installations need permits and inspections, and grid-connected systems need utility interconnection approval. Requirements vary by location.
Can this be installed DIY?
That depends on your jurisdiction and utility. Electrical work must follow manufacturer instructions, adopted code and any licensing requirements.
How do I know which configuration is right for me?
Use our kit selector, or contact SanTan Solar to match the system to your loads, usage and runtime needs.
Still have questions?

Contact SanTan Solar for help matching the system to your project.

Reviews

There are no reviews yet.

Be the first to review “Anker SOLIX E10 Battery Backup Kit (No Solar) | 7.68kW 120/240V | 18.43kWh Battery”

Your email address will not be published. Required fields are marked *

10% OFF PALLETS! – CODE: 10pallets