EG4 · All-In-One Energy Storage System
EG4 XR60 60kWh Hybrid Energy Storage System
A hybrid split-phase inverter and 60 kWh of LFP battery storage, pre-wired in one outdoor NEMA 3R enclosure. Built for high-load homes, rural properties, farms and small businesses that need substantial storage from day one, with up to 26 kW of solar connected directly.
60 kWh
Usable LFP storage (LG cells)
15 kW
Continuous from battery alone; 18 kW with solar
26 kW
Maximum usable solar input
15 years
Warranty, 272 MWh throughput
Key Features
Power for big loads
15 kW continuous from the battery alone and 18 kW with solar, surge up to 24 kW for 10 seconds and 160A motor-starting current, with automatic transfer during outages.
Big solar input
Three MPPTs (2/2/1 inputs) accept up to 26 kW of solar at 100–550 Voc.
Drop-in installation
Arrives pre-assembled with internal battery and control wiring done; set it on the pad and commission it in the EG4 Connect app.
Grid, backup or off-grid
Prioritizes solar self-consumption, supports zero export, and runs grid-tied, off-grid or hybrid, with generator input and Smart Load control.
Scale up to three units
Parallel up to three XR60 units for up to 180 kWh, managed together through an EG4 GridBOSS; 208V three-phase uses three units.
Built to last
LG LFP cells rated for 10,000 cycles, a 15-year warranty and 272 MWh of energy throughput. Certified to UL 9540, UL 9540A and UL 1741 SA/SB, and designed to support domestic content eligibility, with documentation for lease, PPA and TPO projects.
Is the XR60 the Right Fit?
The XR60 fits jobs that need about 60 kWh of storage from day one, installed outdoors at ground level. Smaller, indoor or build-over-time systems usually fit a modular EG4 system better.
High-load homes, rural properties, farms and small businesses
60 kWh of battery and a hybrid inverter in one unit. Confirm that the loads running together, including motor starts, fit about 15 kW from the battery alone.
Substantial storage from day one
Buy once, with no battery additions later. Confirm daily energy needs fit 60 kWh, allowing for the battery’s reserve setting.
Fewer on-site connections
Battery, inverter and internal wiring are connected at the factory; with the pad and site work ready, it typically sets and connects in under a day.
Commercial, agricultural and larger projects
Up to three units per GridBOSS; 208V three-phase uses three units. Multi-unit layouts, combined output and service size are confirmed with EG4.
Consider another EG4 system if
SituationWhyBetter option
Only indoor, garage or wall spaceThe XR60 is outdoor, ground-mounted only.An EG4 system with indoor-rated or wall-mounted equipment.
Flood-prone site or drainage pathNEMA 3R covers rain, sleet and snow, not submersion.Another location on the property, or another EG4 system.
Only a few appliances need backup60 kWh is likely more storage than needed.A smaller EG4 inverter-and-battery system.
Start small and add storage laterMore storage means another complete XR60, not smaller battery packs.A modular system such as an EG4 FlexBOSS21 with WallMount All Weather batteries.
Keep existing solar or batteriesCompatibility can’t be assumed.Send us the exact models; connections to existing EG4 systems go through a GridBOSS in supported setups.
Pairing with the EG4 GridBOSS
A GridBOSS is recommended for most XR60 installs. The EG4 GridBOSS is a 200A microgrid interconnection device (MID) that becomes the hub of the system. With a GridBOSS, the AC-coupled solar, smart loads and backup generator connect to the GridBOSS instead of to each XR60, and the GridBOSS runs them as shared resources using combined data from up to three XR60 units. Each XR60 keeps handling its own inverter and battery control.
AC-coupled solar
Grid-tie-only inverters connect to the GridBOSS, which manages that solar using data from every connected XR60. Keeping existing solar? Send us the exact inverter models first; compatibility isn’t assumed.
Smart loads
Loads such as an EV charger, pool pump or water heater connect to the GridBOSS Smart Port and run based on grid availability, total battery charge, time-of-use settings and solar production.
Backup generator
The generator connects to the GridBOSS, which starts and manages it for the whole system when the grid is down and solar can’t carry the loads.
FunctionXR60 on its ownXR60 with GridBOSS
Grid measurementTwo 1″ CT clamps (included)GridBOSS measures everything; the XR60 CTs aren’t used
GeneratorXR60 generator input (80A), with auto start/stopGridBOSS generator port, managed for all XR60s
AC-coupled solarConnects to the XR60Connects to the GridBOSS
Smart loadsXR60 Smart Load outputGridBOSS Smart Port
Backed-up loadsXR60 Loads port (100A passthrough)Through the GridBOSS; the XR60 Loads port isn’t used
Number of XR60sUp to 3 in parallelUp to 3 per GridBOSS
Planning a GridBOSS system
Configure and parallel the XR60 units first, then configure the GridBOSS, and make sure all units run the latest firmware. In EG4 Connect, choose “Yes, I have GridBOSS” during setup, which skips the CT step. The GridBOSS mounts on a wall rated for its weight; breakers are sold separately (GridBOSS breaker kit available). Wiring options without a GridBOSS include busbar, feeder-tap and supply-side-tap whole-home backup, and off-grid.
What’s in the Box
XR60 unit, pre-assembled4 anchor brackets + 4 stainless flanged screws2 × 1″ CT clampsWi-Fi dongleParallel communication cable (2 m)
An optional EG4 Installer Kit (hitch, wheels, trailer jack) helps move the unit from the crate to its pad. GridBOSS, solar panels, racking, breakers and wiring are sold separately.
Ideal For
High-load homesRural properties and farmsSmall business and light commercialOff-grid propertiesSolar self-consumption & time-of-use
Technical Specifications
Usable capacity60 kWh LFP (LG cells, 10,000 cycles)
Nominal AC voltage120/240V split-phase, 60 Hz
Continuous output15 kW (62.5A) battery only; 18 kW (75A) PV + battery
Rated output power16 kW
Peak surge16–20 kW for 1 min; 20–24 kW for 10 s; >24 kW for 5 s
LRA160A (1 second)
Max AC input (battery charging)16 kW
Max AC passthrough100A
Max generator input current80A
Solar input3 MPPTs, 2/2/1 inputs; 34/34/17A usable (40/40/19A Isc)
DC input voltage100–550 Voc; MPPT 120–440V (full power 250–440V); nominal 360V; startup 150V
Maximum utilized solar26 kW
Parallel unitsUp to 3 (per GridBOSS)
EnclosureNEMA 3R outdoor, ground-mounted only
Operating temperature−13°F to 104°F ambient (thermally limited to keep cells at or below 122°F)
Storage temperature−4°F to 113°F ambient
Humidity / altitude0–85% relative humidity; below 6,562 ft
Dimensions (H × W × D)20.82 × 38.51 × 95.11 in (97.86 in with anchor brackets)
Weight1,584 lb
CertificationsUL 1741 SA/SB, UL 9540, UL 9540A, UL 1973, UL 3141; AFCI per NEC 2020 690.11 / UL 1699B; IEEE 1547:2018, 1547.1:2020, 1547a:2020; CSA C22.2 #107.1, #330, C22.3 #9; California Rule 21 Phase I–III (with compatible gateway); Hawaii Rule 14H; FCC Part 15 Class B; UN38.3
Warranty15 years / 272 MWh
Good to know
Delivered crated by LTL freight; a forklift is required on site to unload it, even with liftgate service, plus a crew. Install outdoors on a level concrete pad or compacted gravel base, away from drainage paths, with the clearances in the EG4 installation manual (working values: 3 ft of working space, about 1 ft between units where the AHJ allows, and 10 ft from combustible vegetation or hazardous materials). Backup time depends on your loads and settings, so we don’t quote a fixed number of hours. Confirm local code, permitting and utility interconnection requirements for your property before installation.
Reviews
There are no reviews yet.